Description
| Country of origin | Germany |
| Nominal voltage U0 | 0.3 kV |
| Nominal voltage U | 0.5 kV |
| Conductor resistance | 20 Ω / km |
| Radiation resistance | 20 x 106 cJ / kg |
| Conductor cross-section S | 1 mm² |
| Conductor diameter S | 8.5 mm |
| Bending radius | 34 mm |
| Conductor class | 5 |
| Number of cores | 3 |
| Type | H05SS-F 300/500 V |
| Type | 3 G 1 RM |
| Core type | RM |
| Core form | Round |
| Core form | Fine stranded |
| Core insulation | EI2 |
| Protective conductor |
X |
| Heat-resistant |
X |
| Flame retardant |
X |
| Indoor use | X |
| Core material | Copper |
| Outer sheath material | Rubber EM9 |
| Outer sheath colour | Black |
| Temperature | -60 …+180 °C |
| Weight | 86 kg / km |
| Standard | DIN VDE 0285-525-2-83 |
| Standard | DIN VDE 0293-308 |
| Standard | DIN VDE 0207-363 |
| Standard | DIN VDE 0295 |
| Standard | DIN EN 50525-2-83 |
| Standard | DIN EN 50363 |
| Standard | DIN EN 60332 |
| Standard | IEC 60228 |
| Standard | IEC 60332 |